Xenon Polarizer Gallery
Click on photos for additional information and description
![Graphical User Interface](https://static.wixstatic.com/media/dc4e4f_536e0b7b930146ae9e5a45226bd86d8d~mv2.jpg/v1/fill/w_147,h_83,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_536e0b7b930146ae9e5a45226bd86d8d~mv2.jpg)
Xeus Graphical User Interface showing advanced user operation
![Xeus Gas Manifold](https://static.wixstatic.com/media/dc4e4f_aa07f2757003476a832f8b11bc4a4269~mv2.jpeg/v1/fill/w_147,h_196,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_aa07f2757003476a832f8b11bc4a4269~mv2.jpeg)
Lower gas handling Manifold with Alicat Pressure controllers and oxygen getters for each inlet gas.
![Laser Alignment](https://static.wixstatic.com/media/dc4e4f_a8ee5c3f016649519e3109c88668d62f~mv2.jpeg/v1/fill/w_147,h_196,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_a8ee5c3f016649519e3109c88668d62f~mv2.jpeg)
Laser being aligned concentrically to the Aluminum Heating/Cooling Jacket which houses the SEOP Cell
![Warer Detection](https://static.wixstatic.com/media/dc4e4f_0320f7ad34fd443ca5554dfa69675471~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_0320f7ad34fd443ca5554dfa69675471~mv2.jpeg)
Manual Operation - Using onboard NMR Spectrometer to acquire proton signal.
![Laser Aligned with Jacket](https://static.wixstatic.com/media/dc4e4f_5f4bf37cb0af400cb2d08932f944a217~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_5f4bf37cb0af400cb2d08932f944a217~mv2.jpeg)
Magnet removed to show Laser with aiming beam on aligned to the SEOP cell and laser reflection optics.
![IR Spectroscopy](https://static.wixstatic.com/media/dc4e4f_7ea059d2a7c24fc298d1e47eb53f2d63~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_7ea059d2a7c24fc298d1e47eb53f2d63~mv2.jpeg)
Onboard IR Spectrometer signal being displayed on the Driver Module to ensure on resonance laser conditions.
![Polarizer with Upper chassis Open](https://static.wixstatic.com/media/dc4e4f_f5be35e9cb704819831f311cddb21451~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_f5be35e9cb704819831f311cddb21451~mv2.jpeg)
Upper chassis open with electromagnet installed.
![Upper Chassis Magnet Removed 1](https://static.wixstatic.com/media/dc4e4f_a91970e44d094104a236ca95b1a09a4d~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_a91970e44d094104a236ca95b1a09a4d~mv2.jpeg)
Electromagnet Removed to show components
![Upper Chassis Magnet Removed 2](https://static.wixstatic.com/media/dc4e4f_c6b35301320741eca755d7490620f579~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_c6b35301320741eca755d7490620f579~mv2.jpeg)
Electromagnet Removed to show components
![Polarized Xenon Detection](https://static.wixstatic.com/media/dc4e4f_7d2e6af63e0147ed93924a7014aa99f0~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_7d2e6af63e0147ed93924a7014aa99f0~mv2.jpeg)
Automated Mode Running SEOP Process. In-situ NMR detection of Xe-129 during the build up process.
![0 - Main Menu](https://static.wixstatic.com/media/dc4e4f_d322ea05f51d40928a7454595d71e3e2~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_d322ea05f51d40928a7454595d71e3e2~mv2.jpeg)
Displaying the Main Menu of the device on the Driver Module which gives access to all other menus.
![1 - Manual Mode](https://static.wixstatic.com/media/dc4e4f_61a737a5d8024fdfb446993359547e29~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_61a737a5d8024fdfb446993359547e29~mv2.jpeg)
The Main Menu allows you to control and have access to settings of individual components.
![2- Advanced Programs](https://static.wixstatic.com/media/dc4e4f_c6459174cbd243e18509dee989b33a1b~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_c6459174cbd243e18509dee989b33a1b~mv2.jpeg)
Under this menu will find 19 Automated procedures and sub-routines which are used to operate the device.
![3 - SEOP Parameters Menu](https://static.wixstatic.com/media/dc4e4f_319b8f7e094c473585c0f9530fea0970~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_319b8f7e094c473585c0f9530fea0970~mv2.jpeg)
The menu stores all the SEOP Parameter for operating the device including max and min set point values used by the automated procedures and sub-routines.
![4 - Calculated Parameters Menu](https://static.wixstatic.com/media/dc4e4f_d724bb4d86534d0faf5430533ae794d8~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_d724bb4d86534d0faf5430533ae794d8~mv2.jpeg)
Values of Calculated Parameters are stored such as the %Xe and rubidium polarization, build up rate, T1-decay, etc
![5 - Measured Paramters Menu](https://static.wixstatic.com/media/dc4e4f_f0b275d87d9b401a8468eb74cfe6c0ff~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_f0b275d87d9b401a8468eb74cfe6c0ff~mv2.jpeg)
Here you filled on all measured signals from the onboard devices such as IR and NMR data which are used for during the calculated parameters.
![6 - Additional Parameters Menu](https://static.wixstatic.com/media/dc4e4f_89a6f2d278784b758e59796b9015d811~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_89a6f2d278784b758e59796b9015d811~mv2.jpeg)
Here all settings relating to instrumentation and NMR settings are stored.
![7 - System Settings Menu](https://static.wixstatic.com/media/dc4e4f_b377833cbfc348b18e8e6cf15458f9ac~mv2.jpeg/v1/fill/w_147,h_110,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/dc4e4f_b377833cbfc348b18e8e6cf15458f9ac~mv2.jpeg)
Here the system default settings are stored. This menu is used to update the device firmware.